How do we clean the woodworking engraving machine everyday?
No matter what material is carved, it is easy to leave scrap or dust everywhere, especially wood products, etc., usually embossed embossed, hollowed out, etc., the most debris, although the effect of these ash is not big, but If there is more accumulation, it will also affect the processing effect of woodworking engraving machine. Therefore, it is very necessary to clean the wood engraving machine regularly. How do we clean the machine in daily work? Let Xiaobian tell everyone.
1. Regularly clean the dust inside the cabinet. There are a lot of circuit boards and electronic parts in the cabinet, and dust is the biggest killer of these electronic products.
2. Clean up the foreign objects on the screw in time, the screw determines the processing precision of the woodworking engraving machine, so it should be cleaned up in time.
3. The guide rail is used as an important part to support the moving beam. It is necessary to clean the guide rail and the surrounding material residue in time to prevent the woodworking engraving machine from getting stuck during the engraving process.
In order to make everyone use the engraving machine better, it is recommended that you clean the dust on the machine after the engraving is completed.
Engraving machine repair
When the engraving machine is not working properly, it may be a problem with its internal components or other reasons. The following is a general introduction to the problems that often arise.
(1) One of the three axes cannot move. In this case, check if the corresponding drive block of the corresponding axis is damaged. The inspection method can use the replacement method: unplug the aviation plug corresponding to the fixed shaft and insert it into the drive corresponding to the other active shaft.
(2) If the non-moving axis moves normally after the exchange, it can be explained that the drive block corresponding to the shaft is damaged, and the drive block needs to be replaced. If the axis is not moving, it means that the cable or motor is faulty. Replace the cable or motor. The three axes cannot move. At this point, check if the three-axis aviation plug is connected to the control box and the control box power is turned on. Whether the data cable is connected to the control box and the control card in the computer mainframe. If all of the above are normal, please contact the factory.
(3) The spindle cannot operate normally. First check the error code displayed on the LED display of the inverter (see the inverter error code item). The following is an example of the YIXING inverter.
YIXING series inverter common faults and treatment (1.5 kW)
Fault code: DL output short circuit Check if the motor and cable are shorted
OL1OL2 load is too large, the motor is blocked, the blockage is eliminated, and the load is reduced.
LU undervoltage input voltage abnormality check input power
OH overheating load is too large. Cooling fan is damaged. Reduce the load and replace the fan. (Note: When the inverter displays DL, the reset button is invalid. Please power off and restart the inverter to eliminate the fault.)
TALENT series inverter common faults and treatment (2.2 kW)
Fault code: EOCD output short circuit Check motor and cable for short circuit
EOU input voltage is too high Check voltage
EOCN output circuit phase-to-phase short circuit or short circuit to ground check wiring and motor
Does the ELU have a large starting current load in the same power system, re-routing to avoid the load?
TL external interference separates the control line from the strong power